SF-Type Wet Scrubber | Emission Controls | PT ZSENG Boilers Indonesia
SF-Type wet scrubber emission control equipment

SF-Type Wet Scrubber / Membrane

Wet-solution emission-control equipment for contaminated industrial gas streams, corrosive gases, fumes and particulate matter.

Emission Controls

SF-Type Wet Scrubbers / Membrane — Wet Solution

Wet scrubbers push contaminated gas streams through a water solution to remove inorganic contaminants. This type of scrubber is commonly used across different industries where corrosive gases or fumes are produced.

Wet scrubbers work by taking contaminated gas through a water-based solution so pollutants can be captured within the wet-treatment process before the gas stream is discharged.

The supplied product material describes wet scrubbing as a more cost-effective solution in the long run when compared with dry scrubber systems.

Particulate-removal information

According to the supplied product material, when functioning properly wet scrubbers can remove over 99% of airborne particulates.

Technical Data

SF-Series Specification & Dimension

The SF-series is available in multiple sizes covering different exhaust-gas volumes. Product drawing and specification information are shown below for technical reference.

SF-Type wet scrubber dimensional product drawing
Product Drawing
SF-Type wet scrubber SF-series specification and dimension chart
Specification & Dimension
Specification SF-1 SF-2 SF-4 SF-6 SF-8 SF-10 SF-15 SF-20 SF-25 SF-35
D 840 1040 1240 1440 1640 1900 2200 2300 2600 3200
D1 600 800 1000 1200 1400 1600 1900 2000 2300 2800
H 5500 5700 5700 6800 8260 10280 11500 12000 13000 15500
H1 1400 1475 1500 1550 1630 1650 1750 2000 1965 2270
H2 2600 2725 2700 3750 4830 5830 6950 7200 8235 10140
H3 1000 1000 1000 1000 1000 2000 2000 2000 2000 2290
H4 500 500 500 500 800 800 800 800 800 800
A 300 450 600 700 850 900 1100 1430 1200 1500
B 150 200 300 400 450 500 500 650 950 900
φ 350 500 600 750 750 800 1000 1000 1200 1600
E 100 100 100 100 100 100 100 100 100 100
F 225 275 350 400 475 550 700 675 675 950
Exhaust Gas Volume (m³/h) 3,000 6,000 12,000 18,000 24,000 30,000 45,000 60,000 75,000 105,000
Weight (kg) 5,000 6,000 7,000 9,000 16,000 21,000 23,000 31,000 42,000 55,000

Dimensional symbols correspond to the SF-Type Wet Scrubber product drawing above. Final equipment selection should be confirmed according to project requirements.

Wet Scrubbing Process

From Contaminated Gas to Wet Treatment

The supplied product description uses a water-based scrubbing process to capture pollutants carried within the industrial gas stream.

01 Gas Entry

Contaminated gas streams containing pollutants, corrosive gases or fumes enter the scrubber system.

02 Wet Contact

The gas stream is brought through a water-based wet scrubbing solution.

03 Pollutant Capture

Pollutants and particulate matter are captured through the wet-treatment process before discharge.

Advantage Features

Characteristics of the Wet Scrubber System

The following points reproduce the principal advantages listed in the supplied SF-Type Wet Scrubber product material.

01

The processing of flue gases can be handled safely.

02

High-temperature and high-humidity gas streams can be handled without condensation issues or temperature limits.

03

Collected particulate matter cannot escape once collected.

04

Some of the more corrosive gases can be effectively neutralized.

05

Solid and gas particulate matter can be absorbed with one system.

06

Large amounts of space are not required for installation of the wet scrubber.

SF-series wet scrubber industrial emission control equipment
Model Selection

Match the SF Model to the Required Gas Volume

The SF-series ranges from SF-1 through SF-35, with the supplied specification table listing exhaust-gas volumes from 3,000 to 105,000 m³/h.

Final model selection should consider the required exhaust-gas volume, physical dimensions, installation space and project operating conditions.

01 Required exhaust-gas volume
02 Available installation dimensions
03 Gas-stream and process conditions

Discuss Your Emission-Control Requirement

Share your exhaust-gas volume, process conditions, installation requirements or available project information with PT ZSENG Boilers Indonesia.

Contact Our Team →